MHBH-NHS 扭環(huán)式傳感器采用外形小、精度高、反應(yīng)靈敏、抗振性好、便于安裝。適用于各種測(cè)力、稱重檢測(cè)裝置的工業(yè)自動(dòng)化測(cè)控系統(tǒng)。
額定載荷 Rated load | 2.2t~330t |
靈敏度 Output sensitivity | 2.85±0.05 mV/V |
非線性 Non-linearity | ±0.05 ~ ±0.1%F?S |
滯后誤差 Lag error | ±0.08 %F?S |
重復(fù)性誤差 Repeatability | ±0.05 %F?S |
蠕變 Creep | ±0.05 %F?S |
零點(diǎn)溫度系數(shù) Zero temperature coefficient | ±0.05 %F?S/10℃ |
靈敏度溫度系數(shù) Sensitivity temperature coefficient | ±0.05 %F?S/10℃ |
輸入電阻 Input resistance | 1.45K±50Ω |
輸出電阻 Input resistance | 1.4K±5Ω |
量程 | ?A | ?B | ?C | H | J | K |
2.2t | ?49 | ?20 | ?60 | 43 | - | 7.5 |
4.7t | ?52 | ?20 | ?60 | 43 | - | 7.5 |
10t | ?75 | ?30 | ?75 | 50 | 7 | 6.5 |
15t | ?75 | ?30 | ?75 | 50 | 7 | 6.5 |
22t | ?75 | ?30 | ?75 | 50 | 7 | 6.5 |
33t | ?95 | ?40 | ?95 | 65 | 7 | 10 |
47t | ?130 | ?60 | ?130 | 75 | 7 | 14 |
68t | ?130 | ?60 | ?130 | 85 | 7 | 14 |
100t | ?150 | ?70 | ?150 | 90 | 7 | 16 |
150t | ?150 | ?70 | ?150 | 100 | 7 | 16 |
220t | ?225 | ?100 | ?225 | 130 | 10 | 24 |
330t | ?225 | ?100 | ?225 | 145 | 10 | 24 |